View In:
ArcGIS Online Map Viewer
Parent Layer:
Pre-2021
Name: DynamicProtectiveDevice
Display Field: CreationUser
Type: Feature Layer
Geometry Type: esriGeometryPoint
Description:
Copyright Text:
Default Visibility: true
MaxRecordCount: 2000
Supported Query Formats: JSON, geoJSON, PBF
Min Scale: 0
Max Scale: 0
Supports Advanced Queries: true
Supports Statistics: true
Can Scale Symbols: false
Use Standardized Queries: true
Supports ValidateSQL: true
Supports Calculate: true
Supports Datum Transformation: true
Extent:
XMin: 1443312.1601596326
YMin: 325853.8099512309
XMax: 1456351.5599338114
YMax: 328458.3900438994
Spatial Reference: 3753
(3753)
Drawing Info:
Renderer:
Unique Value Renderer:
Field 1: SubtypeCD
Field 2: N/A
Field 3: N/A
Field Delimiter: ,
Default Symbol: Style: esriSMSCircle
Color: [130, 130, 130, 255]
Size: 4.0
Angle: 0.0
XOffset: 0
YOffset: 0
Outline:
Default Label:
UniqueValueInfos:
-
Value: 1
Label: Circuit Breaker
Description: N/A
Symbol:
Style: esriSMSCircle
Color: [252, 243, 179, 255]
Size: 4.0
Angle: 0.0
XOffset: 0
YOffset: 0
Outline:
-
Value: 2
Label: Fault Interrupter
Description: N/A
Symbol:
Style: esriSMSCircle
Color: [245, 179, 252, 255]
Size: 4.0
Angle: 0.0
XOffset: 0
YOffset: 0
Outline:
-
Value: 3
Label: Single Phase Hydraulic Recloser
Description: N/A
Symbol:
Style: esriSMSCircle
Color: [182, 228, 252, 255]
Size: 4.0
Angle: 0.0
XOffset: 0
YOffset: 0
Outline:
-
Value: 4
Label: Two Phase Hydraulic Recloser
Description: N/A
Symbol:
Style: esriSMSCircle
Color: [252, 204, 208, 255]
Size: 4.0
Angle: 0.0
XOffset: 0
YOffset: 0
Outline:
-
Value: 5
Label: Three Phase Hydraulic Recloser
Description: N/A
Symbol:
Style: esriSMSCircle
Color: [192, 252, 222, 255]
Size: 4.0
Angle: 0.0
XOffset: 0
YOffset: 0
Outline:
-
Value: 6
Label: Three Phase Electronic Recloser
Description: N/A
Symbol:
Style: esriSMSCircle
Color: [208, 204, 252, 255]
Size: 4.0
Angle: 0.0
XOffset: 0
YOffset: 0
Outline:
-
Value: 7
Label: Three Phase Relay Recloser
Description: N/A
Symbol:
Style: esriSMSCircle
Color: [193, 252, 179, 255]
Size: 4.0
Angle: 0.0
XOffset: 0
YOffset: 0
Outline:
-
Value: 8
Label: Single Phase Hydraulic Sectionalizer
Description: N/A
Symbol:
Style: esriSMSCircle
Color: [252, 192, 229, 255]
Size: 4.0
Angle: 0.0
XOffset: 0
YOffset: 0
Outline:
-
Value: 9
Label: Two Phase Hydraulic Sectionalizer
Description: N/A
Symbol:
Style: esriSMSCircle
Color: [252, 212, 182, 255]
Size: 4.0
Angle: 0.0
XOffset: 0
YOffset: 0
Outline:
-
Value: 10
Label: Three Phase Hydraulic Sectionalizer
Description: N/A
Symbol:
Style: esriSMSCircle
Color: [252, 247, 212, 255]
Size: 4.0
Angle: 0.0
XOffset: 0
YOffset: 0
Outline:
-
Value: 11
Label: Three Phase Electronic Sectionalizer
Description: N/A
Symbol:
Style: esriSMSCircle
Color: [215, 252, 248, 255]
Size: 4.0
Angle: 0.0
XOffset: 0
YOffset: 0
Outline:
Transparency: 0
Labeling Info:
Advanced Query Capabilities:
Supports Statistics: true
Supports OrderBy: true
Supports Distinct: true
Supports Pagination: true
Supports TrueCurve: true
Supports Returning Query Extent: true
Supports Query With Distance: true
Supports Sql Expression: true
Supports Query With ResultType: true
Supports Returning Geometry Centroid: false
Supports Binning LOD: false
Supports Query With LOD Spatial Reference: false
HasZ: false
HasM: false
Has Attachments: false
HTML Popup Type: esriServerHTMLPopupTypeAsHTMLText
Type ID Field: SubtypeCD
Fields:
-
OBJECTID
(
type: esriFieldTypeOID, alias: OBJECTID, editable: false, nullable: false, defaultValue: null, modelName: OBJECTID
)
-
AncillaryRole
(
type: esriFieldTypeSmallInteger, alias: AncillaryRole, editable: true, nullable: true, defaultValue: 0, modelName: AncillaryRole
, Coded Values:
[0: None]
, [1: Source]
, [2: Sink]
)
-
Enabled
(
type: esriFieldTypeSmallInteger, alias: Enabled, editable: true, nullable: true, defaultValue: 1, modelName: Enabled
, Coded Values:
[0: False]
, [1: True]
)
-
CreationUser
(
type: esriFieldTypeString, alias: Creation User, editable: true, nullable: true, length: 50, defaultValue: null, modelName: CreationUser
)
-
DateCreated
(
type: esriFieldTypeDate, alias: Date Created, editable: true, nullable: true, length: 8, defaultValue: null, modelName: DateCreated
)
-
DateModified
(
type: esriFieldTypeDate, alias: Date Modified, editable: true, nullable: true, length: 8, defaultValue: null, modelName: DateModified
)
-
LastUser
(
type: esriFieldTypeString, alias: Last User, editable: true, nullable: true, length: 50, defaultValue: null, modelName: LastUser
)
-
SubtypeCD
(
type: esriFieldTypeInteger, alias: Subtype, editable: true, nullable: true, defaultValue: 6, modelName: SubtypeCD
)
-
FacilityID
(
type: esriFieldTypeString, alias: Facility ID, editable: true, nullable: true, length: 20, defaultValue: null, modelName: FacilityID
)
-
FeederID
(
type: esriFieldTypeString, alias: Feeder ID, editable: true, nullable: true, length: 20, defaultValue: null, modelName: FeederID
)
-
FeederID2
(
type: esriFieldTypeString, alias: Feeder ID 2, editable: true, nullable: true, length: 20, defaultValue: null, modelName: FeederID2
)
-
OperatingVoltage
(
type: esriFieldTypeInteger, alias: Operating Voltage, editable: true, nullable: true, defaultValue: null, modelName: OperatingVoltage
, Coded Values:
[120: 4.16 kV Grounded Y]
, [160: 7.2 kV Grounded Y]
, [210: 12.5 kV Grounded Y]
, ...8 more...
)
-
Comments
(
type: esriFieldTypeString, alias: Comments, editable: true, nullable: true, length: 100, defaultValue: null, modelName: Comments
)
-
WorkOrderID
(
type: esriFieldTypeString, alias: Work Order ID, editable: true, nullable: true, length: 20, defaultValue: null, modelName: WorkOrderID
)
-
InstallationDate
(
type: esriFieldTypeDate, alias: Installation Date, editable: true, nullable: true, length: 8, defaultValue: null, modelName: InstallationDate
)
-
ElectricTraceWeight
(
type: esriFieldTypeInteger, alias: Electric Trace Weight, editable: true, nullable: true, defaultValue: null, modelName: ElectricTraceWeight
)
-
FeederInfo
(
type: esriFieldTypeInteger, alias: Feeder Information, editable: true, nullable: true, defaultValue: null, modelName: FeederInfo
)
-
SymbolRotation
(
type: esriFieldTypeDouble, alias: Symbol Rotation, editable: true, nullable: true, defaultValue: 0, modelName: SymbolRotation
)
-
MaxContinuousCurrent
(
type: esriFieldTypeDouble, alias: Maximum Continuous Current, editable: true, nullable: true, defaultValue: 200, modelName: MaxContinuousCurrent
, Coded Values:
[50: 50 A]
, [100: 100 A]
, [200: 200 A]
, ...7 more...
)
-
MaxInterruptingCurrent
(
type: esriFieldTypeDouble, alias: Maximum Interrupting Current, editable: true, nullable: true, defaultValue: 8000, modelName: MaxInterruptingCurrent
, Coded Values:
[2500: 2.5 kA]
, [4000: 4 kA]
, [6000: 6 kA]
, ...9 more...
)
-
MaxOperatingVoltage
(
type: esriFieldTypeInteger, alias: Maximum Operating Voltage, editable: true, nullable: true, defaultValue: 210, modelName: MaxOperatingVoltage
, Coded Values:
[160: 4.16/7.2 kV]
, [210: 7.2/12.4 kV]
, [230: 7.6/13.2 kV]
, ...3 more...
)
-
NormalPosition_A
(
type: esriFieldTypeInteger, alias: Normal Position - A, editable: true, nullable: true, defaultValue: 1, modelName: NormalPosition_A
, Coded Values:
[1: Closed]
, [0: Open]
, [2: Not Applicable]
)
-
NormalPosition_B
(
type: esriFieldTypeInteger, alias: Normal Position - B, editable: true, nullable: true, defaultValue: 1, modelName: NormalPosition_B
, Coded Values:
[1: Closed]
, [0: Open]
, [2: Not Applicable]
)
-
NormalPosition_C
(
type: esriFieldTypeInteger, alias: Normal Position - C, editable: true, nullable: true, defaultValue: 1, modelName: NormalPosition_C
, Coded Values:
[1: Closed]
, [0: Open]
, [2: Not Applicable]
)
-
PresentPosition_A
(
type: esriFieldTypeInteger, alias: Present Position - A, editable: true, nullable: true, defaultValue: 1, modelName: PresentPosition_A
, Coded Values:
[1: Closed]
, [0: Open]
, [2: Not Applicable]
)
-
PresentPosition_B
(
type: esriFieldTypeInteger, alias: Present Position - B, editable: true, nullable: true, defaultValue: 1, modelName: PresentPosition_B
, Coded Values:
[1: Closed]
, [0: Open]
, [2: Not Applicable]
)
-
PresentPosition_C
(
type: esriFieldTypeInteger, alias: Present Position - C, editable: true, nullable: true, defaultValue: 1, modelName: PresentPosition_C
, Coded Values:
[1: Closed]
, [0: Open]
, [2: Not Applicable]
)
-
LabelText
(
type: esriFieldTypeString, alias: Label Text, editable: true, nullable: true, length: 50, defaultValue: null, modelName: LabelText
)
-
PhaseDesignation
(
type: esriFieldTypeInteger, alias: Phase Designation, editable: true, nullable: true, defaultValue: null, modelName: PhaseDesignation
, Coded Values:
[4: A]
, [6: AB]
, [5: AC]
, ...9 more...
)
-
NominalVoltage
(
type: esriFieldTypeInteger, alias: Nominal Voltage, editable: true, nullable: true, defaultValue: null, modelName: NominalVoltage
, Coded Values:
[100: 4.16 kV]
, [290: 14.4 kV]
, [330: 24.9 kV]
, ...1 more...
)
-
BILRating
(
type: esriFieldTypeInteger, alias: BIL Rating, editable: true, nullable: true, defaultValue: 110, modelName: BILRating
, Coded Values:
[95: 95 BIL]
, [110: 110 BIL]
, [125: 125 BIL]
, ...4 more...
)
-
BypassSwitch
(
type: esriFieldTypeString, alias: Bypass Switch, editable: true, nullable: true, length: 5, defaultValue: null, modelName: BypassSwitch
, Coded Values:
[N: No]
, [Y: Yes]
)
-
ClosingResistor
(
type: esriFieldTypeString, alias: Closing Resistor, editable: true, nullable: true, length: 5, defaultValue: null, modelName: ClosingResistor
, Coded Values:
[NA: Not Applicable]
)
-
GangOperated
(
type: esriFieldTypeString, alias: Gang Operated Indicator, editable: true, nullable: true, length: 5, defaultValue: null, modelName: GangOperated
, Coded Values:
[NA: Not Applicable]
)
-
GroundResistance
(
type: esriFieldTypeDouble, alias: Ground Resistance, editable: true, nullable: true, defaultValue: null, modelName: GroundResistance
)
-
InterruptingMechanism
(
type: esriFieldTypeString, alias: Interrupting Mechanism, editable: true, nullable: true, length: 20, defaultValue: null, modelName: InterruptingMechanism
)
-
InterruptingMedium
(
type: esriFieldTypeString, alias: Interrupting Medium, editable: true, nullable: true, length: 5, defaultValue: OIL, modelName: InterruptingMedium
, Coded Values:
[AIR: Air]
, [OIL: Oil]
, [PUF: Puffer]
, ...3 more...
)
-
MountingType
(
type: esriFieldTypeString, alias: Mounting Type, editable: true, nullable: true, length: 5, defaultValue: null, modelName: MountingType
, Coded Values:
[PAD: Pad Mounted]
, [POL: Pole Mounted]
, [SUB: Substation Frame]
)
-
SCADAControlID
(
type: esriFieldTypeString, alias: SCADA Control ID, editable: true, nullable: true, length: 20, defaultValue: null, modelName: SCADAControlID
)
-
SCADAMonitorID
(
type: esriFieldTypeString, alias: SCADA Monitor ID, editable: true, nullable: true, length: 20, defaultValue: null, modelName: SCADAMonitorID
)
-
ShuntMechanism
(
type: esriFieldTypeString, alias: Shunt Mechanism, editable: true, nullable: true, length: 20, defaultValue: null, modelName: ShuntMechanism
, Coded Values:
[NA: Not Applicable]
)
-
TieSwitchIndicator
(
type: esriFieldTypeString, alias: Tie Switch Indicator, editable: true, nullable: true, length: 5, defaultValue: null, modelName: TieSwitchIndicator
, Coded Values:
[N: No]
, [Y: Yes]
)
-
TripCount
(
type: esriFieldTypeInteger, alias: Trip Count, editable: true, nullable: true, defaultValue: null, modelName: TripCount
, Coded Values:
[0: Not Applicable]
)
-
Manufacturer
(
type: esriFieldTypeString, alias: Manufacturer, editable: true, nullable: true, length: 25, defaultValue: null, modelName: Manufacturer
, Coded Values:
[BRI: Bridges]
, [SIE: Siemens]
, [OTH: Other]
, ...1 more...
)
-
Model
(
type: esriFieldTypeString, alias: Model, editable: true, nullable: true, length: 20, defaultValue: null, modelName: Model
)
-
SerialNumber
(
type: esriFieldTypeString, alias: Serial Number, editable: true, nullable: true, length: 20, defaultValue: null, modelName: SerialNumber
)
-
GlobalID
(
type: esriFieldTypeGlobalID, alias: GlobalID, editable: false, nullable: false, length: 38, defaultValue: null, modelName: GlobalID
)
Types:
ID: 1
Name: Circuit Breaker
Domains:
-
AncillaryRole:
Inherited
-
Enabled:
Inherited
-
OperatingVoltage:
Inherited
-
MaxContinuousCurrent:
Inherited
-
MaxInterruptingCurrent:
Inherited
-
MaxOperatingVoltage:
Inherited
-
NormalPosition_A:
Inherited
-
NormalPosition_B:
Inherited
-
NormalPosition_C:
Inherited
-
PresentPosition_A:
Inherited
-
PresentPosition_B:
Inherited
-
PresentPosition_C:
Inherited
-
PhaseDesignation:
Inherited
-
NominalVoltage:
Coded Values:
[100: 4 kV]
, [190: 8 kV]
, [300: 15 kV]
, ...3 more...
-
BILRating:
Inherited
-
BypassSwitch:
Inherited
-
ClosingResistor:
Coded Values:
[N: No]
, [Y: Yes]
-
GangOperated:
Inherited
-
InterruptingMedium:
Inherited
-
MountingType:
Coded Values:
[NA: Not Applicable]
-
ShuntMechanism:
Inherited
-
TieSwitchIndicator:
Coded Values:
[NA: Not Applicable]
-
TripCount:
Inherited
-
Manufacturer:
Coded Values:
[ABB: ABB/Westinghouse]
, [BB: Brown Boveri]
, [CPR: Cooper/McGraw Edison]
, ...4 more...
Templates:
-
Name: Circuit Breaker
Description:
Prototype:
SerialNumber: null
Model: null
AncillaryRole: 0
Enabled: 1
CreationUser: null
DateCreated: null
DateModified: null
LastUser: null
SubtypeCD: 1
FacilityID: null
FeederID: null
FeederID2: null
OperatingVoltage: null
Comments: null
WorkOrderID: null
InstallationDate: null
ElectricTraceWeight: null
FeederInfo: null
SymbolRotation: 0
MaxContinuousCurrent: 200
MaxInterruptingCurrent: 8000
MaxOperatingVoltage: 210
NormalPosition_A: 1
NormalPosition_B: 1
NormalPosition_C: 1
PresentPosition_A: 1
PresentPosition_B: 1
PresentPosition_C: 1
LabelText: null
PhaseDesignation: 7
NominalVoltage: null
BILRating: 110
BypassSwitch: Y
ClosingResistor: null
GangOperated: NA
GroundResistance: null
InterruptingMechanism: null
InterruptingMedium: OIL
MountingType: null
SCADAControlID: null
SCADAMonitorID: null
ShuntMechanism: NA
TieSwitchIndicator: null
TripCount: 0
Manufacturer: null
Drawing Tool: esriFeatureEditToolPoint
ID: 2
Name: Fault Interrupter
Domains:
-
AncillaryRole:
Inherited
-
Enabled:
Inherited
-
OperatingVoltage:
Inherited
-
MaxContinuousCurrent:
Inherited
-
MaxInterruptingCurrent:
Inherited
-
MaxOperatingVoltage:
Inherited
-
NormalPosition_A:
Inherited
-
NormalPosition_B:
Inherited
-
NormalPosition_C:
Inherited
-
PresentPosition_A:
Inherited
-
PresentPosition_B:
Inherited
-
PresentPosition_C:
Inherited
-
PhaseDesignation:
Inherited
-
NominalVoltage:
Coded Values:
[100: 4 kV]
, [190: 8 kV]
, [300: 15 kV]
, ...3 more...
-
BILRating:
Inherited
-
BypassSwitch:
Coded Values:
[NA: Not Applicable]
-
ClosingResistor:
Inherited
-
GangOperated:
Coded Values:
[N: No]
, [Y: Yes]
-
InterruptingMedium:
Inherited
-
MountingType:
Coded Values:
[NA: Not Applicable]
-
ShuntMechanism:
Inherited
-
TieSwitchIndicator:
Coded Values:
[NA: Not Applicable]
-
TripCount:
Inherited
-
Manufacturer:
Inherited
Templates:
-
Name: Fault Interrupter
Description:
Prototype:
SerialNumber: null
Model: null
AncillaryRole: 0
Enabled: 1
CreationUser: null
DateCreated: null
DateModified: null
LastUser: null
SubtypeCD: 2
FacilityID: null
FeederID: null
FeederID2: null
OperatingVoltage: null
Comments: null
WorkOrderID: null
InstallationDate: null
ElectricTraceWeight: null
FeederInfo: null
SymbolRotation: 0
MaxContinuousCurrent: 200
MaxInterruptingCurrent: 8000
MaxOperatingVoltage: 210
NormalPosition_A: 1
NormalPosition_B: 1
NormalPosition_C: 1
PresentPosition_A: 1
PresentPosition_B: 1
PresentPosition_C: 1
LabelText: null
PhaseDesignation: 7
NominalVoltage: null
BILRating: 110
BypassSwitch: null
ClosingResistor: NA
GangOperated: null
GroundResistance: null
InterruptingMechanism: null
InterruptingMedium: OIL
MountingType: null
SCADAControlID: null
SCADAMonitorID: null
ShuntMechanism: null
TieSwitchIndicator: null
TripCount: null
Manufacturer: OTH
Drawing Tool: esriFeatureEditToolPoint
ID: 3
Name: Single Phase Hydraulic Recloser
Domains:
-
AncillaryRole:
Inherited
-
Enabled:
Inherited
-
OperatingVoltage:
Inherited
-
MaxContinuousCurrent:
Inherited
-
MaxInterruptingCurrent:
Inherited
-
MaxOperatingVoltage:
Inherited
-
NormalPosition_A:
Inherited
-
NormalPosition_B:
Inherited
-
NormalPosition_C:
Inherited
-
PresentPosition_A:
Inherited
-
PresentPosition_B:
Inherited
-
PresentPosition_C:
Inherited
-
PhaseDesignation:
Coded Values:
[4: A]
, [2: B]
, [1: C]
-
NominalVoltage:
Inherited
-
BILRating:
Inherited
-
BypassSwitch:
Inherited
-
ClosingResistor:
Inherited
-
GangOperated:
Inherited
-
InterruptingMedium:
Inherited
-
MountingType:
Inherited
-
ShuntMechanism:
Inherited
-
TieSwitchIndicator:
Inherited
-
TripCount:
Inherited
-
Manufacturer:
Inherited
Templates:
-
Name: Single Phase Hydraulic Recloser
Description:
Prototype:
SerialNumber: null
Model: null
AncillaryRole: 0
Enabled: 1
CreationUser: null
DateCreated: null
DateModified: null
LastUser: null
SubtypeCD: 3
FacilityID: null
FeederID: null
FeederID2: null
OperatingVoltage: null
Comments: null
WorkOrderID: null
InstallationDate: null
ElectricTraceWeight: null
FeederInfo: null
SymbolRotation: 0
MaxContinuousCurrent: 200
MaxInterruptingCurrent: 8000
MaxOperatingVoltage: 210
NormalPosition_A: 1
NormalPosition_B: 1
NormalPosition_C: 1
PresentPosition_A: 1
PresentPosition_B: 1
PresentPosition_C: 1
LabelText: null
PhaseDesignation: null
NominalVoltage: 330
BILRating: 110
BypassSwitch: Y
ClosingResistor: NA
GangOperated: NA
GroundResistance: null
InterruptingMechanism: null
InterruptingMedium: OIL
MountingType: POL
SCADAControlID: null
SCADAMonitorID: null
ShuntMechanism: NA
TieSwitchIndicator: N
TripCount: 0
Manufacturer: null
Drawing Tool: esriFeatureEditToolPoint
ID: 4
Name: Two Phase Hydraulic Recloser
Domains:
-
AncillaryRole:
Inherited
-
Enabled:
Inherited
-
OperatingVoltage:
Inherited
-
MaxContinuousCurrent:
Inherited
-
MaxInterruptingCurrent:
Inherited
-
MaxOperatingVoltage:
Inherited
-
NormalPosition_A:
Inherited
-
NormalPosition_B:
Inherited
-
NormalPosition_C:
Inherited
-
PresentPosition_A:
Inherited
-
PresentPosition_B:
Inherited
-
PresentPosition_C:
Inherited
-
PhaseDesignation:
Coded Values:
[6: AB]
, [5: AC]
, [3: BC]
-
NominalVoltage:
Inherited
-
BILRating:
Inherited
-
BypassSwitch:
Inherited
-
ClosingResistor:
Inherited
-
GangOperated:
Inherited
-
InterruptingMedium:
Inherited
-
MountingType:
Inherited
-
ShuntMechanism:
Inherited
-
TieSwitchIndicator:
Inherited
-
TripCount:
Inherited
-
Manufacturer:
Inherited
Templates:
-
Name: Two Phase Hydraulic Recloser
Description:
Prototype:
SerialNumber: null
Model: null
AncillaryRole: 0
Enabled: 1
CreationUser: null
DateCreated: null
DateModified: null
LastUser: null
SubtypeCD: 4
FacilityID: null
FeederID: null
FeederID2: null
OperatingVoltage: null
Comments: null
WorkOrderID: null
InstallationDate: null
ElectricTraceWeight: null
FeederInfo: null
SymbolRotation: 0
MaxContinuousCurrent: 200
MaxInterruptingCurrent: 8000
MaxOperatingVoltage: 210
NormalPosition_A: 1
NormalPosition_B: 1
NormalPosition_C: 1
PresentPosition_A: 1
PresentPosition_B: 1
PresentPosition_C: 1
LabelText: null
PhaseDesignation: null
NominalVoltage: 330
BILRating: 110
BypassSwitch: Y
ClosingResistor: NA
GangOperated: NA
GroundResistance: null
InterruptingMechanism: null
InterruptingMedium: OIL
MountingType: POL
SCADAControlID: null
SCADAMonitorID: null
ShuntMechanism: NA
TieSwitchIndicator: N
TripCount: 0
Manufacturer: null
Drawing Tool: esriFeatureEditToolPoint
ID: 5
Name: Three Phase Hydraulic Recloser
Domains:
-
AncillaryRole:
Inherited
-
Enabled:
Inherited
-
OperatingVoltage:
Inherited
-
MaxContinuousCurrent:
Inherited
-
MaxInterruptingCurrent:
Inherited
-
MaxOperatingVoltage:
Inherited
-
NormalPosition_A:
Inherited
-
NormalPosition_B:
Inherited
-
NormalPosition_C:
Inherited
-
PresentPosition_A:
Inherited
-
PresentPosition_B:
Inherited
-
PresentPosition_C:
Inherited
-
PhaseDesignation:
Coded Values:
[7: ABC]
-
NominalVoltage:
Inherited
-
BILRating:
Inherited
-
BypassSwitch:
Inherited
-
ClosingResistor:
Inherited
-
GangOperated:
Inherited
-
InterruptingMedium:
Inherited
-
MountingType:
Inherited
-
ShuntMechanism:
Inherited
-
TieSwitchIndicator:
Inherited
-
TripCount:
Inherited
-
Manufacturer:
Inherited
Templates:
-
Name: Three Phase Hydraulic Recloser
Description:
Prototype:
SerialNumber: null
Model: null
AncillaryRole: 0
Enabled: 1
CreationUser: null
DateCreated: null
DateModified: null
LastUser: null
SubtypeCD: 5
FacilityID: null
FeederID: null
FeederID2: null
OperatingVoltage: null
Comments: null
WorkOrderID: null
InstallationDate: null
ElectricTraceWeight: null
FeederInfo: null
SymbolRotation: 0
MaxContinuousCurrent: 200
MaxInterruptingCurrent: 8000
MaxOperatingVoltage: 210
NormalPosition_A: 1
NormalPosition_B: 1
NormalPosition_C: 1
PresentPosition_A: 1
PresentPosition_B: 1
PresentPosition_C: 1
LabelText: null
PhaseDesignation: null
NominalVoltage: 330
BILRating: 110
BypassSwitch: Y
ClosingResistor: NA
GangOperated: NA
GroundResistance: null
InterruptingMechanism: null
InterruptingMedium: OIL
MountingType: POL
SCADAControlID: null
SCADAMonitorID: null
ShuntMechanism: NA
TieSwitchIndicator: N
TripCount: 0
Manufacturer: null
Drawing Tool: esriFeatureEditToolPoint
ID: 6
Name: Three Phase Electronic Recloser
Domains:
-
AncillaryRole:
Inherited
-
Enabled:
Inherited
-
OperatingVoltage:
Inherited
-
MaxContinuousCurrent:
Inherited
-
MaxInterruptingCurrent:
Inherited
-
MaxOperatingVoltage:
Inherited
-
NormalPosition_A:
Inherited
-
NormalPosition_B:
Inherited
-
NormalPosition_C:
Inherited
-
PresentPosition_A:
Inherited
-
PresentPosition_B:
Inherited
-
PresentPosition_C:
Inherited
-
PhaseDesignation:
Coded Values:
[7: ABC]
-
NominalVoltage:
Inherited
-
BILRating:
Inherited
-
BypassSwitch:
Inherited
-
ClosingResistor:
Inherited
-
GangOperated:
Inherited
-
InterruptingMedium:
Inherited
-
MountingType:
Inherited
-
ShuntMechanism:
Inherited
-
TieSwitchIndicator:
Inherited
-
TripCount:
Inherited
Templates:
-
Name: Three Phase Electronic Recloser
Description:
Prototype:
SerialNumber: null
Model: null
AncillaryRole: 0
Enabled: 1
CreationUser: null
DateCreated: null
DateModified: null
LastUser: null
SubtypeCD: 6
FacilityID: null
FeederID: null
FeederID2: null
OperatingVoltage: null
Comments: null
WorkOrderID: null
InstallationDate: null
ElectricTraceWeight: null
FeederInfo: null
SymbolRotation: 0
MaxContinuousCurrent: 200
MaxInterruptingCurrent: 8000
MaxOperatingVoltage: 210
NormalPosition_A: 1
NormalPosition_B: 1
NormalPosition_C: 1
PresentPosition_A: 1
PresentPosition_B: 1
PresentPosition_C: 1
LabelText: null
PhaseDesignation: null
NominalVoltage: 330
BILRating: 110
BypassSwitch: Y
ClosingResistor: NA
GangOperated: NA
GroundResistance: null
InterruptingMechanism: null
InterruptingMedium: OIL
MountingType: POL
SCADAControlID: null
SCADAMonitorID: null
ShuntMechanism: NA
TieSwitchIndicator: N
TripCount: 0
Manufacturer: null
Drawing Tool: esriFeatureEditToolPoint
ID: 7
Name: Three Phase Relay Recloser
Domains:
-
AncillaryRole:
Inherited
-
Enabled:
Inherited
-
OperatingVoltage:
Inherited
-
MaxContinuousCurrent:
Inherited
-
MaxInterruptingCurrent:
Inherited
-
MaxOperatingVoltage:
Inherited
-
NormalPosition_A:
Inherited
-
NormalPosition_B:
Inherited
-
NormalPosition_C:
Inherited
-
PresentPosition_A:
Inherited
-
PresentPosition_B:
Inherited
-
PresentPosition_C:
Inherited
-
PhaseDesignation:
Coded Values:
[7: ABC]
-
NominalVoltage:
Inherited
-
BILRating:
Inherited
-
BypassSwitch:
Inherited
-
ClosingResistor:
Inherited
-
GangOperated:
Inherited
-
InterruptingMedium:
Inherited
-
MountingType:
Inherited
-
ShuntMechanism:
Inherited
-
TieSwitchIndicator:
Inherited
-
TripCount:
Inherited
-
Manufacturer:
Inherited
Templates:
-
Name: Three Phase Relay Recloser
Description:
Prototype:
SerialNumber: null
Model: null
AncillaryRole: 0
Enabled: 1
CreationUser: null
DateCreated: null
DateModified: null
LastUser: null
SubtypeCD: 7
FacilityID: null
FeederID: null
FeederID2: null
OperatingVoltage: null
Comments: null
WorkOrderID: null
InstallationDate: null
ElectricTraceWeight: null
FeederInfo: null
SymbolRotation: 0
MaxContinuousCurrent: 200
MaxInterruptingCurrent: 8000
MaxOperatingVoltage: 210
NormalPosition_A: 1
NormalPosition_B: 1
NormalPosition_C: 1
PresentPosition_A: 1
PresentPosition_B: 1
PresentPosition_C: 1
LabelText: null
PhaseDesignation: null
NominalVoltage: 330
BILRating: 110
BypassSwitch: Y
ClosingResistor: NA
GangOperated: NA
GroundResistance: null
InterruptingMechanism: null
InterruptingMedium: OIL
MountingType: POL
SCADAControlID: null
SCADAMonitorID: null
ShuntMechanism: NA
TieSwitchIndicator: Y
TripCount: 0
Manufacturer: null
Drawing Tool: esriFeatureEditToolPoint
ID: 8
Name: Single Phase Hydraulic Sectionalizer
Domains:
-
AncillaryRole:
Inherited
-
Enabled:
Inherited
-
OperatingVoltage:
Inherited
-
MaxContinuousCurrent:
Inherited
-
MaxInterruptingCurrent:
Inherited
-
MaxOperatingVoltage:
Inherited
-
NormalPosition_A:
Inherited
-
NormalPosition_B:
Inherited
-
NormalPosition_C:
Inherited
-
PresentPosition_A:
Inherited
-
PresentPosition_B:
Inherited
-
PresentPosition_C:
Inherited
-
PhaseDesignation:
Coded Values:
[4: A]
, [2: B]
, [1: C]
-
NominalVoltage:
Coded Values:
[70: 2.4 kV]
, [290: 14.4 kV]
, [330: 24.9 kV]
, ...1 more...
-
BILRating:
Inherited
-
BypassSwitch:
Coded Values:
[NA: Not Applicable]
-
ClosingResistor:
Inherited
-
GangOperated:
Inherited
-
InterruptingMedium:
Inherited
-
MountingType:
Coded Values:
[NA: Not Applicable]
-
ShuntMechanism:
Inherited
-
TieSwitchIndicator:
Coded Values:
[NA: Not Applicable]
-
TripCount:
Inherited
-
Manufacturer:
Inherited
Templates:
-
Name: Single Phase Hydraulic Sectionalizer
Description:
Prototype:
SerialNumber: null
Model: null
AncillaryRole: 0
Enabled: 1
CreationUser: null
DateCreated: null
DateModified: null
LastUser: null
SubtypeCD: 8
FacilityID: null
FeederID: null
FeederID2: null
OperatingVoltage: null
Comments: null
WorkOrderID: null
InstallationDate: null
ElectricTraceWeight: null
FeederInfo: null
SymbolRotation: 0
MaxContinuousCurrent: 200
MaxInterruptingCurrent: 8000
MaxOperatingVoltage: 210
NormalPosition_A: 1
NormalPosition_B: 1
NormalPosition_C: 1
PresentPosition_A: 1
PresentPosition_B: 1
PresentPosition_C: 1
LabelText: null
PhaseDesignation: null
NominalVoltage: null
BILRating: 110
BypassSwitch: null
ClosingResistor: NA
GangOperated: NA
GroundResistance: null
InterruptingMechanism: null
InterruptingMedium: OIL
MountingType: null
SCADAControlID: null
SCADAMonitorID: null
ShuntMechanism: NA
TieSwitchIndicator: null
TripCount: 0
Manufacturer: null
Drawing Tool: esriFeatureEditToolPoint
ID: 9
Name: Two Phase Hydraulic Sectionalizer
Domains:
-
AncillaryRole:
Inherited
-
Enabled:
Inherited
-
OperatingVoltage:
Inherited
-
MaxContinuousCurrent:
Inherited
-
MaxInterruptingCurrent:
Inherited
-
MaxOperatingVoltage:
Inherited
-
NormalPosition_A:
Inherited
-
NormalPosition_B:
Inherited
-
NormalPosition_C:
Inherited
-
PresentPosition_A:
Inherited
-
PresentPosition_B:
Inherited
-
PresentPosition_C:
Inherited
-
PhaseDesignation:
Coded Values:
[6: AB]
, [5: AC]
, [3: BC]
-
NominalVoltage:
Coded Values:
[70: 2.4 kV]
, [290: 14.4 kV]
, [330: 24.9 kV]
, ...1 more...
-
BILRating:
Inherited
-
BypassSwitch:
Coded Values:
[NA: Not Applicable]
-
ClosingResistor:
Inherited
-
GangOperated:
Inherited
-
InterruptingMedium:
Inherited
-
MountingType:
Coded Values:
[NA: Not Applicable]
-
ShuntMechanism:
Inherited
-
TieSwitchIndicator:
Coded Values:
[NA: Not Applicable]
-
TripCount:
Inherited
-
Manufacturer:
Inherited
Templates:
-
Name: Two Phase Hydraulic Sectionalizer
Description:
Prototype:
SerialNumber: null
Model: null
AncillaryRole: 0
Enabled: 1
CreationUser: null
DateCreated: null
DateModified: null
LastUser: null
SubtypeCD: 9
FacilityID: null
FeederID: null
FeederID2: null
OperatingVoltage: null
Comments: null
WorkOrderID: null
InstallationDate: null
ElectricTraceWeight: null
FeederInfo: null
SymbolRotation: 0
MaxContinuousCurrent: 200
MaxInterruptingCurrent: 8000
MaxOperatingVoltage: 210
NormalPosition_A: 1
NormalPosition_B: 1
NormalPosition_C: 1
PresentPosition_A: 1
PresentPosition_B: 1
PresentPosition_C: 1
LabelText: null
PhaseDesignation: null
NominalVoltage: null
BILRating: 110
BypassSwitch: null
ClosingResistor: NA
GangOperated: NA
GroundResistance: null
InterruptingMechanism: null
InterruptingMedium: OIL
MountingType: null
SCADAControlID: null
SCADAMonitorID: null
ShuntMechanism: NA
TieSwitchIndicator: null
TripCount: 0
Manufacturer: null
Drawing Tool: esriFeatureEditToolPoint
ID: 10
Name: Three Phase Hydraulic Sectionalizer
Domains:
-
AncillaryRole:
Inherited
-
Enabled:
Inherited
-
OperatingVoltage:
Inherited
-
MaxContinuousCurrent:
Inherited
-
MaxInterruptingCurrent:
Inherited
-
MaxOperatingVoltage:
Inherited
-
NormalPosition_A:
Inherited
-
NormalPosition_B:
Inherited
-
NormalPosition_C:
Inherited
-
PresentPosition_A:
Inherited
-
PresentPosition_B:
Inherited
-
PresentPosition_C:
Inherited
-
PhaseDesignation:
Coded Values:
[7: ABC]
-
NominalVoltage:
Coded Values:
[70: 2.4 kV]
, [290: 14.4 kV]
, [330: 24.9 kV]
, ...1 more...
-
BILRating:
Inherited
-
BypassSwitch:
Coded Values:
[NA: Not Applicable]
-
ClosingResistor:
Inherited
-
GangOperated:
Inherited
-
InterruptingMedium:
Inherited
-
MountingType:
Coded Values:
[NA: Not Applicable]
-
ShuntMechanism:
Inherited
-
TieSwitchIndicator:
Coded Values:
[NA: Not Applicable]
-
TripCount:
Inherited
-
Manufacturer:
Inherited
Templates:
-
Name: Three Phase Hydraulic Sectionalizer
Description:
Prototype:
SerialNumber: null
Model: null
AncillaryRole: 0
Enabled: 1
CreationUser: null
DateCreated: null
DateModified: null
LastUser: null
SubtypeCD: 10
FacilityID: null
FeederID: null
FeederID2: null
OperatingVoltage: null
Comments: null
WorkOrderID: null
InstallationDate: null
ElectricTraceWeight: null
FeederInfo: null
SymbolRotation: 0
MaxContinuousCurrent: 200
MaxInterruptingCurrent: 8000
MaxOperatingVoltage: 210
NormalPosition_A: 1
NormalPosition_B: 1
NormalPosition_C: 1
PresentPosition_A: 1
PresentPosition_B: 1
PresentPosition_C: 1
LabelText: null
PhaseDesignation: null
NominalVoltage: null
BILRating: 110
BypassSwitch: null
ClosingResistor: NA
GangOperated: NA
GroundResistance: null
InterruptingMechanism: null
InterruptingMedium: OIL
MountingType: null
SCADAControlID: null
SCADAMonitorID: null
ShuntMechanism: NA
TieSwitchIndicator: null
TripCount: 0
Manufacturer: null
Drawing Tool: esriFeatureEditToolPoint
ID: 11
Name: Three Phase Electronic Sectionalizer
Domains:
-
AncillaryRole:
Inherited
-
Enabled:
Inherited
-
OperatingVoltage:
Inherited
-
MaxContinuousCurrent:
Inherited
-
MaxInterruptingCurrent:
Inherited
-
MaxOperatingVoltage:
Inherited
-
NormalPosition_A:
Inherited
-
NormalPosition_B:
Inherited
-
NormalPosition_C:
Inherited
-
PresentPosition_A:
Inherited
-
PresentPosition_B:
Inherited
-
PresentPosition_C:
Inherited
-
PhaseDesignation:
Coded Values:
[7: ABC]
-
NominalVoltage:
Coded Values:
[70: 2.4 kV]
, [290: 14.4 kV]
, [330: 24.9 kV]
, ...1 more...
-
BILRating:
Inherited
-
BypassSwitch:
Coded Values:
[NA: Not Applicable]
-
ClosingResistor:
Inherited
-
GangOperated:
Inherited
-
InterruptingMedium:
Inherited
-
MountingType:
Coded Values:
[NA: Not Applicable]
-
ShuntMechanism:
Inherited
-
TieSwitchIndicator:
Coded Values:
[NA: Not Applicable]
-
TripCount:
Inherited
-
Manufacturer:
Inherited
Templates:
-
Name: Three Phase Electronic Sectionalizer
Description:
Prototype:
SerialNumber: null
Model: null
AncillaryRole: 0
Enabled: 1
CreationUser: null
DateCreated: null
DateModified: null
LastUser: null
SubtypeCD: 11
FacilityID: null
FeederID: null
FeederID2: null
OperatingVoltage: null
Comments: null
WorkOrderID: null
InstallationDate: null
ElectricTraceWeight: null
FeederInfo: null
SymbolRotation: 0
MaxContinuousCurrent: 200
MaxInterruptingCurrent: 8000
MaxOperatingVoltage: 210
NormalPosition_A: 1
NormalPosition_B: 1
NormalPosition_C: 1
PresentPosition_A: 1
PresentPosition_B: 1
PresentPosition_C: 1
LabelText: null
PhaseDesignation: null
NominalVoltage: null
BILRating: 110
BypassSwitch: null
ClosingResistor: NA
GangOperated: NA
GroundResistance: null
InterruptingMechanism: null
InterruptingMedium: OIL
MountingType: null
SCADAControlID: null
SCADAMonitorID: null
ShuntMechanism: NA
TieSwitchIndicator: null
TripCount: 0
Manufacturer: null
Drawing Tool: esriFeatureEditToolPoint
Capabilities: Query,Create,Update,Delete,Uploads,Editing,Sync,Extract
Sync Can Return Changes: true
Is Data Versioned: true
Supports Rollback On Failure: false
Supports ApplyEdits With Global Ids: false
Supports Query With Historic Moment: false
Supports Coordinates Quantization: true
Supported Operations:
Query
Query Attachments
Query Analytic
Apply Edits
Add Features
Update Features
Delete Features
Calculate
Validate SQL
Generate Renderer
Return Updates
Iteminfo
Thumbnail